Monitors — Hit Status docs
A new monitor only counts once it proves it is set up right: two OK checks in a row (heartbeat: the first signal). Until then it shows as In setup: failures…
Monitors
Type · What it checks · Use for
HTTP(S) · Expected HTTP status, response time, redirects; optional: method, headers, body, Basic Auth, certificate alert · Websites, APIs, health checks, portals
Keyword · The page contains (or does not contain) a text · Pages that return 200 even on error ("Internal error" in the HTML)
SSL certificate · TLS chain validity and days until expiry · Any HTTPS domain — alerts before it expires
Heartbeat · Your application calls a URL periodically; no signal in time = incident · Cron jobs, backups, integrations, pods, workers
Ping (ICMP) · ICMP response and latency · Internet links, MPLS, gateways, routers
TCP port · Connection to a port · Databases, SMTP, RDP, VPN, firewalls
DNS · Name resolution (A record) and time · Internal/external DNS servers
Parameters
- Check every: from 20 s to 15 min (depending on the plan). Critical links: 20–60 s; secondary: 5 min.
- Timeout: maximum wait time (default 10 s).
- Degraded above: fixed latency limit that marks degradation (default 300 ms for ping/port, 1.5 s for HTTP), on 2 checks in a row.
- Also degrade when it gets much slower than normal (on by default for HTTP, keyword, ping, port and DNS): compares with this monitor's last 7 days. It is degraded when the answer goes over 4× its normal time (p95) and at least 800 ms more, on 3 checks in a row. A site that answers in 60 ms alerts at about 1 s, without waiting for the fixed limit. The message says how much slower it got ("12× normal").
- Back to normal: after 2 normal answers in a row, so one fast answer in the middle of a slow period does not close and reopen the incident.
- Alert after: how many failed checks in a row before an incident is opened (default 2) — avoids false positives.
- Certificate warning: follows the certificate's lifetime. 90-day certificates (Let's Encrypt and others that renew on their own) warn at 18 days, after the normal renewal window (30 days); one-year certificates at 30 days. A number set on the monitor applies to long-lived certificates.
- Run from: central server or a collector on the customer's network.
Monitor in setup
A new monitor only counts once it proves it is set up right: two OK checks in a row (heartbeat: the first signal). Until then it shows as In setup: failures stay in the history with the reason, but they open no incident, send no alert, page no one and stay out of availability. A monitor that never answered is almost always a wrong address, an internal network or a WAF block, not a system that is down.
- The monitor page shows why it fails and what to do (for example, "the address points to an internal network: use a collector").
- If it still does not work after 1 hour, the admins get one e-mail with the reason and the fix. After 7 days, a second notice, and the monitor checks every 30 minutes until it works.
- Changing a monitor's address, type or collector puts it back in setup: the new target also has to prove it works.
- Added a system that is already down and want to be told when it comes back? On the monitor page, use Turn on alerts now.
Best practices
- One asset per real component; several monitors per asset when it makes sense (HTTPS + SSL + keyword on the same online store).
- For redundant links, add one asset per carrier — the report shows which vendor fails most.
- Use heartbeat for what cannot be "pulled": backups, ETLs, queues, synchronizations.
- Schedule maintenance before interventions: no false alerts and the SLA stays accurate. For routines at the same time (backup, nightly restart), use a recurring window (every day, weekdays or every week). When a monitor fails at the same time on most days, its page suggests the window in one click.